更新时间:2024-03-20 20:43:46 点击:4631次

产品型号 LAMPS
参考报价 返回顶部 面议
基本规格
产品类型 返回顶部 微波等离子体光谱仪
品牌 返回顶部 海阳光学
产地 返回顶部 美国
返回顶部 我来纠错(有奖)
技术参数
其他信息
产品简介 LAMPS激光辅助微波等离子体光谱仪是Ocean Optics公司和Envimetrics公司合作开发的一款新型产品,相对于LIBS技术,LAMPS技术代表了一种巨大的进度。

LAMPS有一个特别设计的微波腔室,它可增强等离子体放电效果,从而提高了大多数潜在化学分析的灵敏度。同时也提高了发射谱线的稳定性和重复性,以获取更好的量化结果。纷杂的各种分析应用要求更高的灵敏度和更少的样品消耗,LAMPS则使这些要求成为可能。

 
LAMPS vs. LIBS Technology
Current LIBS technology permits qualitative analysis of a solid or liquid sample by ablating a minute portion of it, then analyzing the resulting plasma. LAMPS takes this a step further by employing a special microwave cavity. The plasma is injected into this cavity where it reacts with free electrons, greatly increasing sensitivity and producing better line stability and reproducibility. A lower power 50 mJ laser is used in the LAMPS, resulting in less ablation imprint to the sample and greater sensitivity.

LAMPS Components
Spectrometers -- The key to LIBS and LAMPS measurements is the ability to acquire high resolution spectra over a broad wavelength range of a transient event. This is accomplished by coupling 7 HR2000+ spectrometers into one system. Each spectrometer covers ~100-140 nm typically starting at 200nm for Channel A and ending with 980nm for Channel G.

Systems may be configured to start below 200 nm and with fewer channels for element-specific applications. Optical resolution is ~ 0.1nm FWHM. Pixel resolution is ~ 0.05 nm/pixel. In a 7-channel system, there are 14,336 pixels acquiring synchronous spectra. The detector integration time can be as low as 1 ms, and the maximum data transfer rate to the PC is about 500 spectra (14,336 values) per second over the USB 2.0 port.
Sample Chamber -- Provides critical eye safety by using laser safety shielding and safety interlocks on the door. The sample stage is a manual x, y and z positioner, with internal LED illumination for sample positioning. A fiber bundle, inserted inside the microwave cavity, is constructed with a special dielectric tip so that no metals are introduced into the cavity.

The next release will feature a redesign of the power supply so that it will be housed inside the sample chamber, weigh less, and will sustain plasmas greater than 2 ms. CE certification is pending the release of this next generation power supply.

Laser -- We provide Quantel‘s 50 mJ CFR Pulsed Nd:YAG Laser with our LAMPS system. The CFR design is especially rugged as both resonator mirrors are on the same rigid metal plate. The laser is mounted to the sample chamber and aligned to the focusing optics. A 100 mm lens with manual z-axis control permits focusing or allows defocusing of the laser for better plasma uniformity.

Software – OOILIBS operating software provides control of the lasers; has user-programmable delay for the Q switch; acquires, plots and saves spectra; and provides a spectral line library and correlation function for identification of peaks.

Spectra can be exported to Excel. Application-specific libraries of peaks can be loaded. You can zoom into a wavelength range to look for a peak in the library by double-clicking on the line in the table. Or, the correlation routine will match peaks to wavelengths in the library and rank the elements by how many of the emission lines it found. The user can set baseline and peak width filters for the search.



Dimensions:     
LAMPS Sample Chamber
    
72.5 x 35.3 x 43.9 cm
Spectrometer System
    
33.4 x 15.0 x 14.0 cm maximum
Weight:
    
 
LAMPS Sample Chamber
    
22.7 kg
Spectrometer System
    
6.4 kg
Wavelength range
    
200-980 nm (channel dependent)
Optical Resolution
    
~ 0.1nm FWHM
Pixel resolution
    
~ 0.05 nm/pixel
Frame rate
    
2 per second (with microwave on)
Integration time
    
1-2 ms
Trigger delay
    
Programmable in software
Trigger jitter
    
20 ns
Trigger level
    
+5V TTL
Microwave frequency
    
2.45 GHz
Microwave power
    
1 KW @ 2.5 ms


返回顶部
应用文章 返回顶部 此仪器尚未有相关文章
产品样本 此仪器尚未有相关样本
返回顶部
应用范围 返回顶部此仪器尚未有相关应用
用户数 返回顶部 此仪器尚未有用户数
技术创新 此仪器尚未有技术创新
返回顶部
最新动态 返回顶部 此仪器尚未有最新动态
相关视频 返回顶部 此仪器尚未有相关视频
相关耗材和配件 此仪器尚未有相关耗材和配件
返回顶部
相关仪器 返回顶部 此仪器尚未有相关仪器
网友评分

评分:

(0名网友评分)

5星:0人
4星:0人
3星:0人
2星:0人
1星:0人
返回顶部

    该产品暂无相关的供应商

暂无评论